Heat Pump COP / SCOP
Construction CalculatorHeat pump efficiency: COP at flow temp, seasonal SCOP, running cost and CO2 vs gas.
Heat Pump COP / SCOP Calculator: Efficiency, Running Cost & CO₂ vs Gas
A heat pump is judged by one number more than any other: its coefficient of performance. COP tells you how many kilowatt-hours of heat the pump delivers for each kilowatt-hour of electricity it consumes. At a test condition of 7 °C outdoor air and 45 °C flow, a good air-source heat pump might achieve a COP of 3.5–4.0. At design conditions of −3 °C, the same pump may fall to 2.5–3.0. Over a whole heating season, the seasonal coefficient of performance (SCOP) averages those conditions and adds defrost cycles, cycling losses and hot-water demand. The difference between a headline COP of 4.5 and a real-world SCOP of 2.8 is the difference between a system that saves money and one that does not.
The Heat Pump COP / SCOP Calculator is a free online tool that estimates the Carnot COP, the practical COP at a chosen source and flow temperature, the seasonal SCOP, the design-condition COP, annual electricity use, equivalent full-load hours, running cost and CO₂ emissions compared with a gas boiler. It handles air-source, ground-source and water-source heat pumps, and it flags the inputs that most often produce unrealistic results: a flow temperature colder than the source, an ASHP flow above 55 °C, a GSHP design source below 0 °C, a gas efficiency outside 1–100%, and a SCOP below 1.
In this guide, we explain how the calculator works, walk through the formulas, show four worked examples, and answer eight of the most frequently asked questions about heat pump efficiency and running costs.
What Is the Heat Pump COP / SCOP Calculator?
The Heat Pump COP / SCOP Calculator is a free online tool that estimates heat pump efficiency and running cost from a small set of design inputs. It supports:
- Heat pump type: air source (ASHP), ground source (GSHP) or water source (WSHP).
- Rated output in kW.
- Source temperature at the test condition (7 °C for ASHP, about 10 °C for GSHP/WSHP).
- Design source temperature for the design COP (−3 °C for ASHP, ground/water temperature for GSHP/WSHP).
- Flow temperature (35–40 °C for underfloor heating, 45–55 °C for radiators).
- Annual heat demand in kWh, including space heating and hot water.
- Electricity and gas prices per kWh, and gas boiler efficiency.
- Grid CO₂ intensity and gas CO₂ factor for emissions comparison.
The output includes the Carnot COP, the practical COP at the test source temperature, the SCOP, the design COP, the temperature lift at test and design conditions, annual electricity, equivalent full-load hours, heat delivered per kWh of electricity, heat pump annual cost, gas input and annual cost, annual saving with the heat pump, heat pump and gas boiler annual CO₂, and the annual CO₂ saving. Design warnings flag the inputs that are out of range.
The tool complements whole-home heating calculators. For the heat demand that feeds the heat pump, use the Room Heat Loss Calculator; for a boiler comparison, use the Boiler Power Sizing Calculator.
Why Accurate COP and SCOP Estimation Matters
Heat pump running costs are driven by three numbers: the heat demand, the SCOP, and the electricity price. The heat demand is set by the building; the electricity price is set by the tariff; the SCOP is set by the design. A poorly designed heat pump — undersized radiators, a high flow temperature, a cold source — can have an SCOP of 2.2 instead of 3.5. On a 12,000 kWh annual heat demand, that is 5,455 kWh of electricity instead of 3,429 kWh — a 59% increase in running cost.
COP Is a Snapshot, SCOP Is the Season
COP is measured at a single set of conditions, usually 7 °C outdoor air and 35 °C or 45 °C flow. SCOP averages the whole heating season, including colder days when the COP falls, warmer days when the pump cycles, defrost cycles in humid cold weather, and the higher flow temperature needed for hot water. The Energy Saving Trust publishes typical SCOP figures for UK installations, and the calculator’s seasonal factors are aligned with those figures: 0.82 for ASHP and 0.88 for GSHP/WSHP.
Carnot COP Is the Ceiling, Not the Target
The Carnot COP is the theoretical maximum for a reversible heat pump operating between two temperatures. It is calculated as the absolute sink temperature divided by the temperature lift. For a 45 °C flow and 7 °C source, the Carnot COP is about 8.4. No real heat pump reaches that; practical efficiency factors of 0.45–0.55 capture the compressor, refrigerant, heat exchanger and control losses. The calculator shows both figures so the gap between theory and practice is visible.
Flow Temperature Is the Largest Design Lever
Every degree of flow temperature reduction improves COP. A heat pump at 35 °C flow can achieve a COP 20–30% higher than the same pump at 45 °C, and 40–50% higher than at 55 °C. This is why underfloor heating and oversized radiators are specified with heat pumps: they allow a lower flow temperature for the same heat output. The calculator warns when an ASHP flow is above 55 °C, because at that point the efficiency advantage over a gas boiler is largely lost. The GOV.UK guidance on heat pumps explains the relationship between flow temperature and efficiency in domestic retrofit.
Source Temperature Matters More for ASHP
An ASHP’s source temperature varies with the weather: 7 °C on a mild day, −3 °C at design, and lower during a cold snap. A GSHP’s source is the ground, which stays at 8–12 °C all year, and a WSHP’s source is a water body at a similar temperature. That stability is why GSHP and WSHP achieve higher SCOP than ASHP in the same building. The calculator uses a separate design source temperature so the design COP reflects the actual source, not a fixed ASHP assumption.
Annual Electricity Is the Cost Driver
Annual electricity is annual heat demand divided by SCOP. A 12,000 kWh heat demand at SCOP 3.5 uses 3,429 kWh of electricity; at SCOP 2.5 it uses 4,800 kWh. At £0.24/kWh, the difference is £329 a year. The calculator shows the annual electricity separately from the cost, so the effect of a design change can be seen before the tariff is applied.
Gas Comparison Needs Efficiency
A gas boiler’s running cost is the annual heat demand divided by boiler efficiency, multiplied by the gas price. A 90% boiler uses 13,333 kWh of gas for 12,000 kWh of heat; an 80% boiler uses 15,000 kWh. The calculator applies the efficiency you enter, so the comparison is like-for-like. The Ofgem price cap information explains how gas and electricity unit rates differ, and why the running-cost comparison depends on the tariff as much as the efficiency.
CO₂ Comparison Completes the Picture
A heat pump’s emissions depend on the grid carbon intensity; a gas boiler’s emissions depend on the gas CO₂ factor. With a UK grid intensity of about 0.193 kg CO₂/kWh, a heat pump at SCOP 3.5 emits about 0.055 kg CO₂ per kWh of heat, compared with 0.183 kg for a 100% efficient gas boiler — a reduction of about 70%. The calculator shows both figures and the annual saving, which is useful for energy audits and retrofit decisions.
Design Checks Prevent Plausible but Wrong Results
The most dangerous heat pump estimate is the one that looks reasonable but is based on a wrong input. A flow temperature colder than the source, a GSHP design source of −3 °C, a gas efficiency of 150%, or a SCOP below 1 will all produce numbers that look like results but are not. The calculator flags these cases explicitly, so the result is either correct or visibly incomplete.
How to Use the Heat Pump COP / SCOP Calculator
The calculator takes eleven inputs. Each is described below.
1. Heat Pump Type
Select air source, ground source or water source. The type sets the practical efficiency factor and the seasonal SCOP factor: ASHP 0.45 and 0.82; GSHP/WSHP 0.55 and 0.88.
2. Rated Output
Enter the nominal heating capacity in kW at design conditions. This is used only for the equivalent full-load hours calculation; it does not affect COP or SCOP.
3. Source Temperature
Enter the source temperature at the test condition. For ASHP, 7 °C is the standard test point. For GSHP, use the ground temperature (about 10 °C). For WSHP, use the water body temperature.
4. Design Source Temperature
Enter the source temperature at design conditions. For ASHP, use the local external design temperature (typically −3 °C in the UK). For GSHP/WSHP, use the ground or water temperature (typically 10 °C). The calculator warns if a GSHP/WSHP design source is below 0 °C.
5. Flow Temperature
Enter the flow temperature to the emitters. Underfloor heating typically runs at 35–40 °C; radiators at 45–55 °C; hot water at 55–60 °C. Lower flow temperatures improve COP.
6. Annual Heat Demand
Enter the annual space heating and hot water demand in kWh. This is the heat delivered to the building, not the electricity consumed.
7. Electricity Price
Enter the electricity price per kWh. Leave at 0 to skip the heat pump cost rows.
8. Gas Price
Enter the gas price per kWh for the comparison. Leave at 0 to skip the gas cost rows.
9. Gas Boiler Efficiency
Enter the gas boiler efficiency in percent. Modern condensing boilers are 90–98%; older non-condensing boilers are 78–85%. The calculator clamps the value to 1–100% and warns if it is outside that range.
10. Grid CO₂ Intensity
Enter the grid carbon intensity in kg CO₂/kWh. The UK average is about 0.193 kg CO₂/kWh; adjust for your region or tariff.
11. Gas CO₂ Factor
Enter the gas CO₂ factor in kg CO₂/kWh. Natural gas combustion is about 0.183 kg CO₂/kWh.
Reading the Output
- Carnot COP is the theoretical maximum for the test temperatures.
- COP at source temperature is the practical COP at the test point.
- SCOP is the seasonal average after the type-specific factor.
- Design COP is the COP at the design source temperature.
- Temperature lift at test and design conditions shows how hard the pump is working.
- Annual electricity is the heat demand divided by SCOP.
- Equivalent full-load hours is the heat demand divided by rated output.
- Heat delivered per kWh electricity is the SCOP expressed as kWh/kWh.
- Heat pump annual cost, gas input, gas annual cost and annual saving are shown when prices are entered.
- Heat pump and gas CO₂, and the annual CO₂ saving, are shown when CO₂ factors are entered.
- Design warnings flag inputs that are out of range.
Understanding the Calculations
All calculations are deterministic and can be reproduced by hand. This section lists the formulas.
Absolute Temperatures
Source (K) = source temperature + 273.15
Sink (K) = flow temperature + 273.15
Temperature Lift
Lift (K) = sink − source
Carnot COP
Carnot COP = sink / lift
Practical COP
COP = Carnot COP × efficiency factor
Efficiency factors: ASHP 0.45, GSHP 0.55, WSHP 0.55.
SCOP
SCOP = COP × seasonal factor
Seasonal factors: ASHP 0.82, GSHP 0.88, WSHP 0.88.
Design COP
Design COP = (sink / design lift) × efficiency factor
Design lift = sink − design source (K).
Annual Electricity
Annual electricity (kWh) = annual heat demand / SCOP
Equivalent Full-Load Hours
Equivalent hours = annual heat demand / rated output
Gas Input and Cost
Gas input (kWh) = annual heat demand / gas boiler efficiency
Gas cost = gas input × gas price
Heat Pump Cost
Heat pump cost = annual electricity × electricity price
Saving
Saving = gas cost − heat pump cost
CO₂
Heat pump CO₂ (kg) = annual electricity × grid CO₂ intensity
Gas boiler CO₂ (kg) = gas input × gas CO₂ factor
CO₂ saving = gas CO₂ − heat pump CO₂
Quick Reference
- 45 °C flow, 7 °C source: Carnot ≈ 8.37; ASHP COP ≈ 3.77; SCOP ≈ 3.09.
- 45 °C flow, −3 °C design: ASHP design COP ≈ 2.98.
- 35 °C flow, 7 °C source: Carnot ≈ 10.2; ASHP COP ≈ 4.59; SCOP ≈ 3.76.
- 12,000 kWh heat at SCOP 3.09: annual electricity ≈ 3,883 kWh.
- 12,000 kWh heat at 90% gas: gas input ≈ 13,333 kWh.
- At £0.24/kWh electricity and £0.07/kWh gas: heat pump cost ≈ £932; gas cost ≈ £933; saving ≈ £1.
- CO₂: heat pump ≈ 750 kg; gas ≈ 2,440 kg; saving ≈ 1,690 kg.
For unit conversion after sizing, use the BTU / kW Converter Calculator; for hot-water demand, use the Hot Water Tank Sizing Calculator.
Worked Examples
Example 1: ASHP, 45 °C Flow, 7 °C Source, 12,000 kWh Heat
Inputs: ASHP, 8 kW, source 7 °C, design source −3 °C, flow 45 °C, annual heat 12,000 kWh, electricity £0.24/kWh, gas £0.07/kWh, gas efficiency 90%, grid CO₂ 0.193, gas CO₂ 0.183.
- Sink = 318.15 K; source = 280.15 K; lift = 38 K.
- Carnot = 318.15 / 38 = 8.37.
- COP = 8.37 × 0.45 = 3.77.
- SCOP = 3.77 × 0.82 = 3.09.
- Design source = 270.15 K; design lift = 48 K; design COP = (318.15 / 48) × 0.45 = 2.98.
- Annual electricity = 12,000 / 3.09 = 3,883 kWh.
- Equivalent hours = 12,000 / 8 = 1,500 h.
- Heat pump cost = 3,883 × £0.24 = £932.
- Gas input = 12,000 / 0.90 = 13,333 kWh; gas cost = 13,333 × £0.07 = £933.
- Saving = £933 − £932 = £1.
- Heat pump CO₂ = 3,883 × 0.193 = 749 kg.
- Gas CO₂ = 13,333 × 0.183 = 2,440 kg.
- CO₂ saving = 1,691 kg.
Result: at these tariffs, the heat pump and gas boiler running costs are almost identical, but the heat pump saves about 1.7 tonnes of CO₂ a year. A lower electricity tariff or a higher SCOP would produce a positive cost saving.
Example 2: ASHP, 35 °C Flow, 7 °C Source, 12,000 kWh Heat
Inputs: same as Example 1 but flow 35 °C.
- Sink = 308.15 K; lift = 28 K.
- Carnot = 308.15 / 28 = 11.01.
- COP = 11.01 × 0.45 = 4.95.
- SCOP = 4.95 × 0.82 = 4.06.
- Annual electricity = 12,000 / 4.06 = 2,956 kWh.
- Heat pump cost = 2,956 × £0.24 = £709.
- Saving vs gas = £933 − £709 = £224.
- Heat pump CO₂ = 2,956 × 0.193 = 571 kg.
- CO₂ saving = 2,440 − 571 = 1,869 kg.
Result: reducing the flow temperature from 45 °C to 35 °C cuts annual electricity by 24% and produces a £224 annual saving. This is the single most important design decision for a heat pump.
Example 3: GSHP, 45 °C Flow, 10 °C Source
Inputs: GSHP, 8 kW, source 10 °C, design source 10 °C, flow 45 °C, annual heat 12,000 kWh, electricity £0.24/kWh, gas £0.07/kWh, gas efficiency 90%.
- Sink = 318.15 K; source = 283.15 K; lift = 35 K.
- Carnot = 318.15 / 35 = 9.09.
- COP = 9.09 × 0.55 = 5.00.
- SCOP = 5.00 × 0.88 = 4.40.
- Annual electricity = 12,000 / 4.40 = 2,727 kWh.
- Heat pump cost = 2,727 × £0.24 = £654.
- Saving vs gas = £933 − £654 = £279.
- Heat pump CO₂ = 2,727 × 0.193 = 526 kg.
- CO₂ saving = 2,440 − 526 = 1,914 kg.
Result: a ground-source heat pump with a stable 10 °C source achieves a higher SCOP than an ASHP at the same flow temperature, producing a £279 annual saving and a larger CO₂ reduction.
Example 4: Unrealistic Flow — Warning
Inputs: ASHP, source 7 °C, flow 5 °C.
- Lift = 5 − 7 = −2 K.
- Warning: “Flow temperature must be warmer than source temperature.”
- The calculation uses a safe lift of 1 K, producing a Carnot COP of about 281 — a physically meaningless result.
Result: the warning prevents the result from being used. A heat pump cannot deliver heat at a flow temperature colder than its source.
Benefits of Using the Heat Pump COP / SCOP Calculator
Tips for Accurate Heat Pump COP and SCOP Estimation
- Use the flow temperature the emitters actually need. A radiator system designed for 55 °C will not achieve the SCOP of an underfloor system at 35 °C.
- Use the local design source temperature for ASHP. −3 °C is a common UK default; −5 °C in colder regions.
- Use ground temperature for GSHP. 8–12 °C is typical; a design source below 0 °C is almost always an input error.
- Include hot water in the annual heat demand. DHW is often 20–30% of the total and is delivered at a higher flow temperature, so it lowers the effective SCOP.
- Use a realistic electricity tariff. A heat pump tariff or time-of-use tariff can be significantly cheaper than the standard rate.
- Use the gas price you actually pay, including standing charges if relevant. The comparison is only as good as the tariff inputs.
- Check the SCOP against manufacturer data. A datasheet SCOP at 35 °C flow is not the same as a real installation at 45 °C.
- Do not compare a lab COP with a real SCOP. The lab COP is a snapshot; the SCOP is the season.
- Consider defrost losses for ASHP. In humid cold weather, defrost cycles reduce the effective COP; the seasonal factor captures this in a simplified way.
- Use the CO₂ comparison for retrofit decisions. A heat pump may be cost-neutral at current tariffs but still reduce emissions by 60–70%.
Common Mistakes to Avoid
- Using the Carnot COP as the expected COP. No real heat pump reaches the Carnot limit.
- Using a fixed −3 °C design source for a GSHP. Ground temperature is stable and positive; a negative design source is an input error.
- Sizing a heat pump at 55 °C flow and expecting a high SCOP. High flow temperatures reduce efficiency.
- Ignoring hot water in the annual heat demand. DHW lowers the effective SCOP.
- Comparing a heat pump’s COP with a gas boiler’s efficiency directly. COP and efficiency are different metrics; compare running cost and CO₂ instead.
- Using a gas efficiency above 100%. No boiler is more than 100% efficient on a gross calorific value basis.
- Ignoring the electricity tariff. A heat pump at SCOP 4 can still be expensive on a high-rate tariff.
- Forgetting CO₂. A heat pump’s emissions depend on the grid; a clean grid makes the heat pump much cleaner than gas.
- Using a SCOP below 1 as a design target. That means the heat pump uses more electricity than heat delivered.
- Not checking the design warnings. They catch the inputs that produce plausible but wrong results.
How to Improve Heat Pump Efficiency and Reduce Running Costs
If the calculated SCOP is lower than expected, here are ways to improve it without changing the heat pump:
- Lower the flow temperature. Increase radiator sizes or add underfloor heating to allow 35–40 °C flow instead of 45–55 °C.
- Improve the building fabric. Better insulation and draught-proofing reduce the heat demand and allow a lower flow temperature.
- Use weather compensation. A heat pump that modulates flow temperature with outdoor temperature runs more efficiently than one at a fixed high flow.
- Separate hot water from space heating. A dedicated DHW cylinder at 55 °C is more efficient than raising the whole heating circuit to 60 °C.
- Choose a heat pump tariff. Time-of-use or heat pump tariffs can reduce the electricity cost per kWh.
- Optimise defrost. Correct installation and drainage reduce defrost losses in ASHP.
- Size the heat pump correctly. An oversized heat pump cycles more and runs at a lower efficiency.
- Maintain the system. Dirty filters, low refrigerant charge and incorrect settings reduce COP.
- Use the CO₂ comparison. Even when cost-neutral, a heat pump often reduces emissions significantly.
Frequently Asked Questions (FAQ)
Conclusion
The Heat Pump COP / SCOP Calculator turns a heat pump’s headline efficiency into a realistic seasonal figure. It shows the Carnot COP, the practical COP at the test source temperature, the SCOP, the design COP, the temperature lift, annual electricity, equivalent full-load hours, heat delivered per kWh of electricity, running cost, gas comparison and CO₂ emissions. It also flags the inputs that most often produce plausible but wrong results: a flow temperature colder than the source, an ASHP flow above 55 °C, a GSHP design source below 0 °C, a gas efficiency outside 1–100%, and a SCOP below 1.
Use it to compare an ASHP with a GSHP, to test the effect of a lower flow temperature, to estimate annual electricity and running cost, or to quantify the CO₂ saving against a gas boiler. A heat pump is only as efficient as its design allows — and the design starts with the numbers this calculator makes visible.